home *** CD-ROM | disk | FTP | other *** search
/ Columbia Kermit / kermit.zip / newsgroups / misc.19970929-19971216 / 000243_news@newsmaster….columbia.edu _Fri Nov 7 08:54:17 1997.msg < prev    next >
Internet Message Format  |  2020-01-01  |  2KB

  1. Return-Path: <news@newsmaster.cc.columbia.edu>
  2. Received: from newsmaster.cc.columbia.edu (newsmaster.cc.columbia.edu [128.59.35.30])
  3.     by watsun.cc.columbia.edu (8.8.5/8.8.5) with ESMTP id IAA12913
  4.     for <kermit.misc@watsun.cc.columbia.edu>; Fri, 7 Nov 1997 08:54:16 -0500 (EST)
  5. Received: (from news@localhost)
  6.     by newsmaster.cc.columbia.edu (8.8.5/8.8.5) id IAA04902
  7.     for kermit.misc@watsun; Fri, 7 Nov 1997 08:54:16 -0500 (EST)
  8. Path: news.columbia.edu!watsun.cc.columbia.edu!fdc
  9. From: fdc@watsun.cc.columbia.edu (Frank da Cruz)
  10. Newsgroups: comp.protocols.kermit.misc
  11. Subject: Re: Kermit 95 (Windows NT): can't open multi-ports
  12. Date: 7 Nov 1997 13:54:13 GMT
  13. Organization: Columbia University
  14. Lines: 26
  15. Message-ID: <63v6i5$akj$1@apakabar.cc.columbia.edu>
  16. References: <63urqb$tvk$1@duke.telepac.pt>
  17. NNTP-Posting-Host: watsun.cc.columbia.edu
  18. Xref: news.columbia.edu comp.protocols.kermit.misc:8027
  19.  
  20. In article <63urqb$tvk$1@duke.telepac.pt>,
  21. Paul Vieira <cel@mail.telepac.pt> wrote:
  22. : I have a multi-port board (4 Com's) in my PC and  I have 3 extern
  23. : modems connected to them. I use 3 Kermit 95 scripts (one for each COM)
  24. : to receive files from outside PC's. If I put this working on Windows
  25. : 95, everything works fine. If I use Windows NT 4.0, then Kermit 95
  26. : only can open one COM (when it tries to open the others it shows a
  27. : message: "Sorry, can't open connection: com ..."
  28. :
  29. : The multi-port uses the same IRQ for all the COM's.
  30. : Why does it works fine with Windows 95 and with Windows NT it doesn't?
  31. If you can use a port with Hyperterminal, then you can also use it with
  32. Kermit 95 1.1.13 as a TAPI device (see UPDATES.TXT section 6.10).
  33.  
  34. If you can't use it with Hyperterminal, then you have a Windows
  35. configuration issue because Kermit must access the ports through the
  36. Windows drivers.  As you probably know, PCs are not well designed to use
  37. more than 2 COM ports (some might say they are not well designed to use
  38. more than zero COM ports) because of the shortage of hardware interrupts
  39. (inter alia).  Thus, if you are having trouble with multiple COM ports,
  40. it is your job to configure your PC in such a way that each port can be
  41. used.  Sometimes you have to sacrifice some other device, like your
  42. sound board.
  43.  
  44. - Frank